PRCD-K Personal protection intermediate switch

  • Any residual currents caused by defective loads are recognised in fractions of a second and the power supply is interrupted. The PRCD-K therefore offers reliable protection against electric shocks and is approved by the employers' liability insurance association in accordance with DGUV 203-032.
  • Plastic housing with function display and test circuit
  • Operation via ON button, test button O ~ TEST
  • Rated residual current: 30 mA
  • Triggering time less than 30 ms
  • IP55: protected against dust and water jets
  • 230 V, 16 A, 50 Hz, max. 3,600 W

Opis

PRCD-K when using mobile generators

With Connection of electrical equipment to a standardised power generator the German Social Accident Insurance recommends in DGUV Information 203-032 the Use of suitable protective measures. The PRCD-K has been developed for these special applications and serves as a Protection level increase.

You can read more information in our Flyer.

Versions

PRCD-K Personal protection circuit-breaker PU Item no.
for own installation on the supply line 1 45400

Details

Security

Tested according to:
DIN VDE 0661

[1085][1243][1581]
Technical data

230 V, 16 A, max. 3,600 W

[DE]
Use
[1][2][3]

When is a PRCD-K required?
If you use a mobile power generator on the construction site!

  • If you operate electrical equipment, such as tools, via a commercially available power generator, connect the equipment via a PRCD-K.
  • When using submersible pumps, unintentional switching off of the submersible pump due to possible potential equalisation currents is prevented if a PRCD-K is connected to a power generator with an earthing connection.
More Products