PRCD-S safety cable reel

Brand:

Xpert's PRCD-S safety cable reel

  • Drum body made of robust, highly break-resistant special plastic
  • with sturdy, shock-absorbing X-double tube frame with star grip brake
  • Frame with ergonomic, non-slip 2-component handle and cable guide
  • with site cable made of polyurethane H07BQ-F 3G2,5
  • with built-in thermal circuit breaker
  • with PRCD-S personal protection circuit breaker (art. no. 45305)
  • with 3 earthed socket outlets with safety hinged lids and hammer marks
  • Fehlerströme werden in Sekundenbruchteilen erkannt und die Stromzufuhr wird unterbrochen. Der PRCD-S bietet somit zuverlässigen Schutz vor Stromschlägen und ist von der Berufsgenossenschaft zugelassen.
  • ACHTUNG: Die Einschalttaste des PRCD-S muss mit bloßer Hand betätigt werden, damit die Schutzfunktion einsetzt. Nicht mit Handschuhen benutzen!
  • IP44: protected against foreign bodies and splash water

Opis

Als PRCD-S (Portable Residual Current Device-Safety) werden ortsveränderliche Fehlerstromschutzeinrichtungen mit Schutzleitererkennung bzw. Schutzleiterüberwachung bezeichnet. Sie dienen dem Schutz von Personen vor
Elektrounfällen und werden wie ein Verlängerungskabel zwischen einen elektrischen Verbraucher, z. B. ein Elektrowerkzeug, und eine Steckdose angeschlossen.

Further information can be found here

Versions

Xpert's PRCD-S safety cable reel ø mm PU/pallet Item no.
40 m site cable made of polyurethane H07BQ-F 3G2,5 320 1/48 23829

Details

Security

Tested according to:
DIN VDE 0661:1988-04
EN 61242
DIN VDE 0620-2-1
DIN EN 50525-2

[1081][1085][1243][1246][1369]
Technical data

Rated residual current: 30 mA
Trigger time: &lt 30 ms
230 V, 16 A, max. 3500 W

[DE]
Use
[1][2][3]

How does a PRCD-S work?
When attempting to switch on the PRCD-S, the wiring of the supply line is checked. The PRCD-S can only be switched on if the wiring is faultless. Only then can the connected appliance be switched on. With this function, the PRCD-S prevents accidents caused by faulty electrical installations, such as a missing protective earth conductor. Such faults can usually only be recognised by closer inspection and are therefore particularly dangerous. A PRCD-S only offers this protection if it is switched on without gloves, i.e. with direct skin contact, as a measurement of the earth potential through the user's body is carried out during the switch-on process. During operation of the electrical load, the PRCD-S assumes the function of a residual current circuit breaker and thus protects the user against dangerous currents that can be caused by defective electrical equipment. In addition, the PRCD-S has an undervoltage release. This prevents devices, such as cut-off grinders, from switching on again automatically after a power failure as soon as power is available again.

Why do we strongly recommend using it?
Many electrical accidents can be avoided by using a PRCD-S. In order to increase safety, especially on construction sites, the BG BAU has therefore drawn up an accident prevention regulation which states that:
"A company must ensure that the electrical systems and equipment may only be operated in accordance with the electrotechnical regulations and that any defects identified must be rectified immediately. If there is an urgent danger, the defective equipment must not be used."
To comply with this regulation, use cables with built-in PRCD-S on the construction site! Companies and employees are therefore on the safe side, investing directly in health and saving money in the long term.

More Products