PRCD extension cable

Categories: , SKU: 45222
  • Heavy rubber hose line
  • mit Schutzkontaktstecker und -kupplung mit Schutzkappe
  • with function display and test circuit, with electronic measuring device
  • Bemessungsfehlerstrom 30 mA
  • Auslösezeit <30 ms
  • 230 V, 16 A, max. 3,500 W
  • IP44: protected against foreign bodies and splash water

Opis

Versions

PRCD extension cable PU Item no.
2 x 1,5 m H07RN-F 3G1,5 1 45222

Details

Security

Tested according to
DIN VDE 0620
VDE 0661
DIN EN 50525-2

[1081][1085]
Technical data

230 V, 16 A, max. 3.5 kW
Bemessungsfehlerstrom 30 mA
Auslösezeit &lt30 mS

[DE]
Use
[1][2]

What is the difference between a PRCD and a PRCD-S?

The PRCD is a portable personal protection switch with an electronic residual current release and undervoltage release.

  • It recognises residual currents that occur, for example, when a faulty electrical appliance is touched and interrupts the current so quickly that life-threatening accidents can be prevented.
  • It also has an undervoltage release that switches off in the event of a mains voltage failure to prevent secondary accidents.

The PRCD-S is an all-pole switching, portable residual current device with electronic residual current evaluation, designed as an intermediate cord device.

Additional functions compared to the PRCD:

  • Check the socket outlet to ensure that phase L, neutral conductor N and protective conductor PE are present, correctly connected and not reversed.
  • Only allows power to be drawn from a safe socket.
  • Checks the protective conductor when switching on.
  • Monitors the protective conductor during operation.
  • Cannot be switched on if a fault is detected.
  • Switches off automatically as soon as a fault occurs (e.g. protective conductor breakage).
  • Schaltet nicht ab, wenn der Schutzleiter mit Fremdspannung beaufschlagt wird, z. B. durch Anbohren einer
  • Fremdleitung. Da der PRCD-S in diesem Fall nicht abschaltet, kann das vorgeschaltete Schutzorgan ansprechen und den Stromkreis unterbrechen.

The employers' liability insurance associations recommend As a supply point on small construction sites Protective distribution boards and portable protective devices with protective conductor monitoring (PRCD-S)!

More Products