<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Personal protection | as - Schwabe</title>
	<atom:link href="https://as-schwabe.de/eng/produkt-kategorie/personenschutz/feed/" rel="self" type="application/rss+xml" />
	<link>https://as-schwabe.de/eng</link>
	<description>German quality for construction power and lighting.</description>
	<lastbuilddate>Wed, 15 Oct 2025 18:05:29 +0000</lastbuilddate>
	<language>en-GB</language>
	<sy:updateperiod>
	hourly	</sy:updateperiod>
	<sy:updatefrequency>
	1	</sy:updatefrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://as-schwabe.de/wp-content/uploads/2024/12/as-schwabe_favicon-2.png</url>
	<title>Personal protection | as - Schwabe</title>
	<link>https://as-schwabe.de/eng</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>PRCD-K personal protection extension</title>
		<link>https://as-schwabe.de/eng/product/prcd-k-personal-protection-extension/</link>
		
		<dc:creator><![CDATA[Josephine Schueler-Erbel]]></dc:creator>
		<pubdate>Wed, 19 Feb 2025 14:21:31 +0000</pubdate>
				<guid ispermalink="false">https://as-schwabe.de/?post_type=product&#038;p=12562</guid>

					<description><![CDATA[<ul>
<li>for use on power generators</li>
<li>2x 1.5m H07BQ-F 3G2.5, orange with earthing contact plug and coupling with protective cap</li>
<li>with KOPP PRCD-K intermediate switch 30mA (190400015) in accordance with DGUV-I 203-032</li>
<li>3-pole switching</li>
<li>in polybag with label</li>
<li>IP44: protected against foreign bodies and splash water</li>
</ul>
<p>The post <a href="https://as-schwabe.de/eng/product/prcd-k-personal-protection-extension/">PRCD-K personal protection extension</a> first appeared on <a href="https://as-schwabe.de/eng">as - Schwabe</a>.</p>]]></description>
										<content:encoded><![CDATA[<p><strong>PRCD-K when using mobile generators</strong></p>
<p>With <strong>Connection of electrical equipment to a standardised power generator</strong> the German Social Accident Insurance recommends in DGUV Information 203-032 the <strong>Use of suitable protective measures</strong>. The <strong>PRCD-K</strong> has been developed for these special applications and serves as a <strong>Protection level increase</strong>.</p>
<p>You can read more information in our <a href="t3://file?uid=2522">Flyer</a>.</p>
<h3>Versions</h3>
<table>
<thead>
<tr>
<th scope="col"></th>
<th scope="col">PU</th>
<th scope="col">Item no.</th>
</tr>
</thead>
<tbody>
<tr>
<td>PRCD-K extension cable</td>
<td>1</td>
<td>45401</td>
</tr>
</tbody>
</table>
<h3>Details</h3>
<table>
<thead>
<tr>
<th>Security</th>
</tr>
</thead>
<tbody>
<tr>
<td>Tested according to:<br />
DIN VDE 0661:1988-04<br />
DIN EN 50525-2<br />
DIN VDE 0620</p>
<p><img decoding="async" src="https://as-schwabe.de/wp-content/uploads/2024/12/IP44_.svg" alt="[1081]" /><img decoding="async" src="https://as-schwabe.de/wp-content/uploads/2024/12/CE_schwarz.svg" alt="[1085]" /><img decoding="async" src="https://as-schwabe.de/wp-content/uploads/2024/12/BGI_2019.svg" alt="[1243]" /><img decoding="async" src="https://as-schwabe.de/wp-content/uploads/2024/12/Icon_K2_2019.svg" alt="[1246]" /><img decoding="async" src="https://as-schwabe.de/wp-content/uploads/2025/01/Icon_PRCDS_nicht_mit_Handschuhen_verwenden_01.svg" alt="[1486]" /></td>
</tr>
</tbody>
</table>
<table>
<thead>
<tr>
<th>Technical data</th>
</tr>
</thead>
<tbody>
<tr>
<td>230 V, 16 A, 30mA</p>
<p><img decoding="async" src="https://as-schwabe.de/wp-content/uploads/2024/12/Icon_Made_in_Germany.svg" alt="[DE]" /></td>
</tr>
</tbody>
</table>
<table>
<thead>
<tr>
<th>Use</th>
</tr>
</thead>
<tbody>
<tr>
<td><img decoding="async" src="https://as-schwabe.de/wp-content/uploads/2024/12/as-schwabe-technik-produkte-einsatzgebiet-gewerbe-icon-1.svg" alt="[1]" /><img decoding="async" src="https://as-schwabe.de/wp-content/uploads/2024/12/as-schwabe-technik-produkte-einsatzgebiet-aussen-icon.svg" alt="[2]" /><img decoding="async" src="https://as-schwabe.de/wp-content/uploads/2024/12/as-schwabe-technik-produkte-einsatzgebiet-innen-icon.svg" alt="[3]" /></td>
</tr>
</tbody>
</table><p>The post <a href="https://as-schwabe.de/eng/product/prcd-k-personal-protection-extension/">PRCD-K personal protection extension</a> first appeared on <a href="https://as-schwabe.de/eng">as - Schwabe</a>.</p>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>PRCD-K Personal protection intermediate switch</title>
		<link>https://as-schwabe.de/eng/product/prcd-k-personal-protection-intermediate-switch/</link>
		
		<dc:creator><![CDATA[wp-as-admin]]></dc:creator>
		<pubdate>Tue, 07 Jan 2025 03:49:58 +0000</pubdate>
				<guid ispermalink="false">https://as2025.as-schwabe.de/?post_type=product&#038;p=9673</guid>

					<description><![CDATA[<ul>
<li>Any residual currents caused by defective loads are recognised in fractions of a second and the power supply is interrupted. The PRCD-K therefore offers reliable protection against electric shocks and is approved by the employers' liability insurance association in accordance with DGUV 203-032.</li>
<li>Plastic housing with function display and test circuit</li>
<li>Operation via ON button, test button O ~ TEST</li>
<li>Rated residual current: 30 mA</li>
<li>Triggering time less than 30 ms</li>
<li>IP55: protected against dust and water jets</li>
<li>230 V, 16 A, 50 Hz, max. 3,600 W</li>
</ul>
<p>The post <a href="https://as-schwabe.de/eng/product/prcd-k-personal-protection-intermediate-switch/">PRCD-K Personal protection intermediate switch</a> first appeared on <a href="https://as-schwabe.de/eng">as - Schwabe</a>.</p>]]></description>
										<content:encoded><![CDATA[<p><strong>PRCD-K when using mobile generators</strong></p>
<p>With <strong>Connection of electrical equipment to a standardised power generator</strong> the German Social Accident Insurance recommends in DGUV Information 203-032 the <strong>Use of suitable protective measures</strong>. The <strong>PRCD-K</strong> has been developed for these special applications and serves as a <strong>Protection level increase</strong>.</p>
<p>You can read more information in our <a href="t3://file?uid=2522">Flyer</a>.</p>
<h3>Versions</h3>
<table>
<thead>
<tr>
<th class="text-left" scope="col">PRCD-K Personal protection circuit-breaker</th>
<th scope="col">PU</th>
<th class="text-right" scope="col">Item no.</th>
</tr>
</thead>
<tbody>
<tr>
<td>for own installation on the supply line</td>
<td class="text-center">1</td>
<td class="text-right">45400</td>
</tr>
</tbody>
</table>
<h3>Details</h3>
<div class="table-container">
<table>
<thead>
<tr>
<th>Security</th>
</tr>
</thead>
<tbody>
<tr>
<td>
<div>
<p>Tested according to:<br />
DIN VDE 0661</p>
</div>
<div class="image-cell"><img decoding="async" src="https://as-schwabe.de/wp-content/uploads/2024/12/CE_schwarz.svg" alt="[1085]" /><img decoding="async" src="https://as-schwabe.de/wp-content/uploads/2024/12/BGI_2019.svg" alt="[1243]" /><img decoding="async" src="https://as-schwabe.de/wp-content/uploads/2025/01/IP55_01.svg" alt="[1581]" /></div>
</td>
</tr>
</tbody>
</table>
<table>
<thead>
<tr>
<th>Technical data</th>
</tr>
</thead>
<tbody>
<tr>
<td>230 V, 16 A, max. 3,600 W</p>
<div class="image-cell"><img decoding="async" src="https://as-schwabe.de/wp-content/uploads/2024/12/Icon_Made_in_Germany.svg" alt="[DE]" /></div>
</td>
</tr>
</tbody>
</table>
<table>
<thead>
<tr>
<th>Use</th>
</tr>
</thead>
<tbody>
<tr>
<td>
<div class="image-cell"><img decoding="async" src="https://as-schwabe.de/wp-content/uploads/2024/12/as-schwabe-technik-produkte-einsatzgebiet-gewerbe-icon-1.svg" alt="[1]" /><img decoding="async" src="https://as-schwabe.de/wp-content/uploads/2024/12/as-schwabe-technik-produkte-einsatzgebiet-aussen-icon.svg" alt="[2]" /><img decoding="async" src="https://as-schwabe.de/wp-content/uploads/2024/12/as-schwabe-technik-produkte-einsatzgebiet-innen-icon.svg" alt="[3]" /></div>
</td>
</tr>
</tbody>
</table>
</div>
<p><strong>When is a PRCD-K required?<br />
If you use a mobile power generator on the construction site! </strong></p>
<ul>
<li>If you operate electrical equipment, such as tools, via a commercially available power generator, connect the equipment via a PRCD-K.</li>
<li>When using submersible pumps, unintentional switching off of the submersible pump due to possible potential equalisation currents is prevented if a PRCD-K is connected to a power generator with an earthing connection.</li>
</ul><p>The post <a href="https://as-schwabe.de/eng/product/prcd-k-personal-protection-intermediate-switch/">PRCD-K Personal protection intermediate switch</a> first appeared on <a href="https://as-schwabe.de/eng">as - Schwabe</a>.</p>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>PRCD-S power distributor</title>
		<link>https://as-schwabe.de/eng/product/prcd-s-power-distributor/</link>
		
		<dc:creator><![CDATA[wp-as-admin]]></dc:creator>
		<pubdate>Tue, 07 Jan 2025 03:46:22 +0000</pubdate>
				<guid ispermalink="false">https://as2025.as-schwabe.de/?post_type=product&#038;p=9111</guid>

					<description><![CDATA[<ul>
<li>Input: CEE plug 400 V, 16 A, 5-pin</li>
<li>               2 m H07RN-F 5G2.5 heavy-duty rubber hose cable </li>
<li>Output: 4x 230 V, 16 A socket outlets with earthing contact<br /> 	                2x CEE sockets 400 V, 16 A, 5-pin</li>
<li>Fuse protection: 1x RCD 40 A, 30 mA, type A</li>
<li>1x protective conductor monitoring module</li>
<li>Robust solid rubber housing</li>
<li>Dimensions (LxWxH): 400x400x330 mm</li>
<li>Weight: 7.9 kg</li>
<li>IP44: protected against foreign bodies and splash water</li>
</ul>
<p>The post <a href="https://as-schwabe.de/eng/product/prcd-s-power-distributor/">PRCD-S power distributor</a> first appeared on <a href="https://as-schwabe.de/eng">as - Schwabe</a>.</p>]]></description>
										<content:encoded><![CDATA[<p><strong>What is a PRCD-S?</strong><br /> Portable residual current devices with protective conductor detection or protective conductor monitoring are known as PRCD-S (Portable Residual Current Device-Safety). They are used to protect people from electrical accidents and are connected like an extension cable between an electrical load, e.g. a power tool, and a socket outlet.</p>
<p>Further information can be found <a href="t3://file?uid=1315" target="_blank">here</a>.</p>
<h3>Versions</h3>
<table>
<thead>
<tr>
<th class="text-left" scope="col">PRCD-S power distributor</th>
<th scope="col">PU</th>
<th class="text-right" scope="col">Item no.</th>
</tr>
</thead>
<tbody>
<tr>
<td>400 V / 16 A / 30 mA</td>
<td class="text-center">1</td>
<td class="text-right">45416</td>
</tr>
</tbody>
</table>
<h3>Details</h3>
<div class="table-container">
<table>
<thead>
<tr>
<th>Security</th>
</tr>
</thead>
<tbody>
<tr>
<td>
<div>
<p>Tested according to<br /> DIN VDE 0661:1988-04<br /> DIN VDE 0620<br /> DIN EN 50525-2<br /> EN 60309</p>
</div>
<div class="image-cell"><img decoding="async" src="https://as-schwabe.de/wp-content/uploads/2024/12/IP44_.svg" alt="[1081]" /><img decoding="async" src="https://as-schwabe.de/wp-content/uploads/2024/12/CE_schwarz.svg" alt="[1085]" /><img decoding="async" src="https://as-schwabe.de/wp-content/uploads/2024/12/BGI_2019.svg" alt="[1243]" /><img decoding="async" src="https://as-schwabe.de/wp-content/uploads/2024/12/Icon_K2_2019.svg" alt="[1246]" /><img decoding="async" src="https://as-schwabe.de/wp-content/uploads/2025/01/Icon_PRCDS_nicht_mit_Handschuhen_verwenden_01.svg" alt="[1486]" /></div>
</td>
</tr>
</tbody>
</table>
<table>
<thead>
<tr>
<th>Technical data</th>
</tr>
</thead>
<tbody>
<tr>
<td>
<p>400 V, 16 A, max. 11 kW <br /> Rated residual current 30 mA<br /> Release time &amp;lt30 mS</p>
<div class="image-cell"><img decoding="async" src="https://as-schwabe.de/wp-content/uploads/2024/12/Icon_Made_in_Germany.svg" alt="[DE]" /></div>
</td>
</tr>
</tbody>
</table>
<table>
<thead>
<tr>
<th>Use</th>
</tr>
</thead>
<tbody>
<tr>
<td>
<div class="image-cell"><img decoding="async" src="https://as-schwabe.de/wp-content/uploads/2024/12/as-schwabe-technik-produkte-einsatzgebiet-gewerbe-icon-1.svg" alt="[1]" /><img decoding="async" src="https://as-schwabe.de/wp-content/uploads/2024/12/as-schwabe-technik-produkte-einsatzgebiet-aussen-icon.svg" alt="[2]" /><img decoding="async" src="https://as-schwabe.de/wp-content/uploads/2024/12/as-schwabe-technik-produkte-einsatzgebiet-innen-icon.svg" alt="[3]" /></div>
</td>
</tr>
</tbody>
</table></div>
<p><strong>How does a PRCD-S work?</strong><br /> When attempting to switch on the PRCD-S, the wiring of the supply line is checked. The PRCD-S can only be switched on if the wiring is faultless. Only then can the connected appliance be switched on. With this function, the PRCD-S prevents accidents caused by faulty electrical installations, such as a missing protective earth conductor. Such faults can usually only be recognised by closer inspection and are therefore particularly dangerous. A PRCD-S only offers this protection if it is switched on without gloves, i.e. with direct skin contact, as a measurement of the earth potential through the user's body is carried out during the switch-on process. During operation of the electrical load, the PRCD-S assumes the function of a residual current circuit breaker and thus protects the user against dangerous currents that can be caused by defective electrical equipment. In addition, the PRCD-S has an undervoltage release. This prevents devices, such as cut-off grinders, from switching on again automatically after a power failure as soon as power is available again.</p>
<p><strong>Why do we strongly recommend using it?</strong><br /> The Institute for Research into Electrical Accidents (BG ETEM) counted more than 3800 electrical accidents in 2018. Many of these can be avoided by using a PRCD-S. In order to increase safety, especially on construction sites, the BG BAU has therefore drawn up an accident prevention regulation which states that: "A company must ensure that electrical installations and equipment may only be operated in accordance with electrotechnical regulations and that any defects found must be rectified immediately. If there is an urgent danger, the defective equipment must not be used." To comply with this regulation, use cables with built-in PRCD-S on the construction site. Companies and employees are therefore on the safe side, investing directly in health and saving money in the long term.</p><p>The post <a href="https://as-schwabe.de/eng/product/prcd-s-power-distributor/">PRCD-S power distributor</a> first appeared on <a href="https://as-schwabe.de/eng">as - Schwabe</a>.</p>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>PRCD personal protection adapter plug</title>
		<link>https://as-schwabe.de/eng/product/prcd-personal-protection-adapter/</link>
		
		<dc:creator><![CDATA[wp-as-admin]]></dc:creator>
		<pubdate>Tue, 07 Jan 2025 03:46:22 +0000</pubdate>
				<guid ispermalink="false">https://as2025.as-schwabe.de/?post_type=product&#038;p=9113</guid>

					<description><![CDATA[<ul>
<li>30 mA personal protection adapter plug</li>
<li>Undervoltage release</li>
<li>Triggering time less than 30 ms</li>
<li>Reliable protection against dangerous electric shocks</li>
<li>Fault currents are detected in fractions of a second and the power supply is interrupted</li>
<li>with function display and test circuit, with electronic measuring device</li>
<li>230 V, 16 A, max. 3,500 W</li>
</ul>
<p>The post <a href="https://as-schwabe.de/eng/product/prcd-personal-protection-adapter/">PRCD personal protection adapter plug</a> first appeared on <a href="https://as-schwabe.de/eng">as - Schwabe</a>.</p>]]></description>
										<content:encoded><![CDATA[<h3>Versions</h3>
<table>
<thead>
<tr>
<th class="text-left" scope="col">Personal protection intermediate switch</th>
<th scope="col">PU</th>
<th class="text-right" scope="col">Item no.</th>
</tr>
</thead>
<tbody>
<tr>
<td>For plugging in via a plug</td>
<td class="text-center">1</td>
<td class="text-right">45230</td>
</tr>
</tbody>
</table>
<h3>Details</h3>
<div class="table-container">
<table>
<thead>
<tr>
<th>Security</th>
</tr>
</thead>
<tbody>
<tr>
<td>
<div>
<p>Tested according to:<br /> DIN VDE 0620<br /> VDE 0661 </p>
</div>
<div class="image-cell"><img decoding="async" src="https://as-schwabe.de/wp-content/uploads/2024/12/IP44_.svg" alt="[1081]" /><img decoding="async" src="https://as-schwabe.de/wp-content/uploads/2024/12/CE_schwarz.svg" alt="[1085]" /></div>
</td>
</tr>
</tbody>
</table>
<table>
<thead>
<tr>
<th>Technical data</th>
</tr>
</thead>
<tbody>
<tr>
<td>
<p>230 V, 16 A, max. 3,500 W</p>
<div class="image-cell"><img decoding="async" src="https://as-schwabe.de/wp-content/uploads/2024/12/Icon_Made_in_Germany.svg" alt="[DE]" /></div>
</td>
</tr>
</tbody>
</table>
<table>
<thead>
<tr>
<th>Use</th>
</tr>
</thead>
<tbody>
<tr>
<td>
<div class="image-cell"><img decoding="async" src="https://as-schwabe.de/wp-content/uploads/2024/12/as-schwabe-technik-produkte-einsatzgebiet-gewerbe-icon-1.svg" alt="[1]" /><img decoding="async" src="https://as-schwabe.de/wp-content/uploads/2024/12/as-schwabe-technik-produkte-einsatzgebiet-aussen-icon.svg" alt="[2]" /></div>
</td>
</tr>
</tbody>
</table></div>
<p><strong>What is the difference between a PRCD and a PRCD-S?</strong></p>
<p> The PRCD is a portable personal protection switch with an electronic residual current release and undervoltage release.</p>
<ul>
<li>It recognises residual currents that occur, for example, when a faulty electrical appliance is touched and interrupts the current so quickly that life-threatening accidents can be prevented.</li>
<li>It also has an undervoltage release that switches off in the event of a mains voltage failure to prevent secondary accidents.</li>
</ul>
<p> The PRCD-S is an all-pole switching, portable residual current device with electronic residual current evaluation, designed as an intermediate cord device.</p>
<p> <strong>Additional functions compared to the PRCD:</strong></p>
<ul>
<li>Check the socket outlet to ensure that phase L, neutral conductor N and protective conductor PE are present, correctly connected and not reversed.</li>
<li>Only allows power to be drawn from a safe socket.</li>
<li>Checks the protective conductor when switching on.</li>
<li>Monitors the protective conductor during operation.</li>
<li>Cannot be switched on if a fault is detected.</li>
<li>Switches off automatically as soon as a fault occurs (e.g. protective conductor breakage).</li>
<li>Does not switch off if external voltage is applied to the protective conductor, e.g. by drilling into an external cable. As the PRCD-S does not switch off in this case, the upstream protective device may respond and interrupt the circuit.</li>
</ul>
<p><strong>The employers' liability insurance associations recommend</strong> As a supply point on small construction sites Protective distribution boards and portable protective devices with protective conductor monitoring (PRCD-S)!</p><p>The post <a href="https://as-schwabe.de/eng/product/prcd-personal-protection-adapter/">PRCD personal protection adapter plug</a> first appeared on <a href="https://as-schwabe.de/eng">as - Schwabe</a>.</p>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>PRCD-S Personal protection intermediate switch</title>
		<link>https://as-schwabe.de/eng/product/prcd-s-personal-protection-intermediate-switch/</link>
		
		<dc:creator><![CDATA[wp-as-admin]]></dc:creator>
		<pubdate>Tue, 07 Jan 2025 03:45:44 +0000</pubdate>
				<guid ispermalink="false">https://as2025.as-schwabe.de/?post_type=product&#038;p=9008</guid>

					<description><![CDATA[<ul>
<li class="translation-block">Fault currents are detected in fractions of a second and the power supply is interrupted. The <strong>PRCD-S</strong> therefore offers reliable protection against electric shocks and is approved by the employers' liability insurance association.</li>
<li class="translation-block"><strong>CAUTION:</strong> The switch-on button of the<strong> PRCD-S</strong> must be pressed with the bare hand to activate the protective function. Do not use with gloves!</li>
<li>Plastic housing with function display and test circuit</li>
<li>Rated residual current: 30 mA</li>
<li>Triggering time less than 30 ms</li>
<li>IP55: protected against dust and water jets</li>
<li>230 V, 16 A, max. 3,500 W</li>
</ul>
<p>The post <a href="https://as-schwabe.de/eng/product/prcd-s-personal-protection-intermediate-switch/">PRCD-S Personal protection intermediate switch</a> first appeared on <a href="https://as-schwabe.de/eng">as - Schwabe</a>.</p>]]></description>
										<content:encoded><![CDATA[<p><strong>What is a PRCD-S?</strong><br /> Portable residual current devices with protective conductor detection or protective conductor monitoring are known as PRCD-S (Portable Residual Current Device-Safety). They are used to protect people from electrical accidents and are connected like an extension cable between an electrical load, e.g. a power tool, and a socket outlet.<br /> You can find more information <a href="t3://file?uid=1315" target="_blank" title="PRCD-S Personal protection">here</a></p>
<h3>Versions</h3>
<table>
<thead>
<tr>
<th class="text-left" scope="col">PRCD-S Personal protection circuit-breaker</th>
<th scope="col">PU</th>
<th class="text-right" scope="col">Item no.</th>
</tr>
</thead>
<tbody>
<tr>
<td>for own installation on the supply line</td>
<td class="text-center">1</td>
<td class="text-right">45305</td>
</tr>
</tbody>
</table>
<h3>Details</h3>
<div class="table-container">
<table>
<thead>
<tr>
<th>Security</th>
</tr>
</thead>
<tbody>
<tr>
<td>
<div>
<p>Tested according to:<br /> DIN VDE 0661:1988-04</p>
</div>
<div class="image-cell"><img decoding="async" src="https://as-schwabe.de/wp-content/uploads/2024/12/CE_schwarz.svg" alt="[1085]" /><img decoding="async" src="https://as-schwabe.de/wp-content/uploads/2024/12/BGI_2019.svg" alt="[1243]" /><img decoding="async" src="https://as-schwabe.de/wp-content/uploads/2024/12/Icon_K2_2019.svg" alt="[1246]" /><img decoding="async" src="https://as-schwabe.de/wp-content/uploads/2025/01/Icon_PRCDS_nicht_mit_Handschuhen_verwenden_01.svg" alt="[1486]" /><img decoding="async" src="https://as-schwabe.de/wp-content/uploads/2025/01/IP55_01.svg" alt="[1581]" /></div>
</td>
</tr>
</tbody>
</table>
<table>
<thead>
<tr>
<th>Technical data</th>
</tr>
</thead>
<tbody>
<tr>
<td>
<p>230 V, 16 A, max. 3,500 W</p>
<div class="image-cell"><img decoding="async" src="https://as-schwabe.de/wp-content/uploads/2024/12/Icon_Made_in_Germany.svg" alt="[DE]" /></div>
</td>
</tr>
</tbody>
</table>
<table>
<thead>
<tr>
<th>Use</th>
</tr>
</thead>
<tbody>
<tr>
<td>
<div class="image-cell"><img decoding="async" src="https://as-schwabe.de/wp-content/uploads/2024/12/as-schwabe-technik-produkte-einsatzgebiet-gewerbe-icon-1.svg" alt="[1]" /><img decoding="async" src="https://as-schwabe.de/wp-content/uploads/2024/12/as-schwabe-technik-produkte-einsatzgebiet-aussen-icon.svg" alt="[2]" /><img decoding="async" src="https://as-schwabe.de/wp-content/uploads/2024/12/as-schwabe-technik-produkte-einsatzgebiet-innen-icon.svg" alt="[3]" /></div>
</td>
</tr>
</tbody>
</table></div>
<p><strong>How does a PRCD-S work?</strong><br /> When attempting to switch on the PRCD-S, the wiring of the supply line is checked. The PRCD-S can only be switched on if the wiring is faultless. Only then can the connected appliance be switched on. With this function, the PRCD-S prevents accidents caused by faulty electrical installations, such as a missing protective earth conductor. Such faults can usually only be recognised by closer inspection and are therefore particularly dangerous. A PRCD-S only offers this protection if it is switched on without gloves, i.e. with direct skin contact, as a measurement of the earth potential through the user's body is carried out during the switch-on process. During operation of the electrical load, the PRCD-S assumes the function of a residual current circuit breaker and thus protects the user against dangerous currents that can be caused by defective electrical equipment. In addition, the PRCD-S has an undervoltage release. This prevents devices, such as cut-off grinders, from switching on again automatically after a power failure as soon as power is available again.</p>
<p> <strong>Why do we strongly recommend using it?</strong><br /> The Institute for Research into Electrical Accidents (BG ETEM) counted more than 3800 electrical accidents in 2018. Many of these can be avoided by using a PRCD-S. In order to increase safety, especially on construction sites, the BG BAU has therefore drawn up an accident prevention regulation which states that: "A company must ensure that electrical installations and equipment may only be operated in accordance with electrotechnical regulations and that any defects found must be rectified immediately. If there is an urgent danger, the defective equipment must not be used." To comply with this regulation, use cables with built-in PRCD-S on the construction site. Companies and employees are therefore on the safe side, investing directly in health and saving money in the long term.</p><p>The post <a href="https://as-schwabe.de/eng/product/prcd-s-personal-protection-intermediate-switch/">PRCD-S Personal protection intermediate switch</a> first appeared on <a href="https://as-schwabe.de/eng">as - Schwabe</a>.</p>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>PRCD-S extension cables</title>
		<link>https://as-schwabe.de/eng/product/prcd-s-extension-cables/</link>
		
		<dc:creator><![CDATA[wp-as-admin]]></dc:creator>
		<pubdate>Tue, 07 Jan 2025 03:45:44 +0000</pubdate>
				<guid ispermalink="false">https://as2025.as-schwabe.de/?post_type=product&#038;p=9009</guid>

					<description><![CDATA[<ul>
<li>2x 1.5 m H07BQ-F 3G2.5 construction site cable made of polyurethane with earthing contact plug</li>
<li>with PRCD-S personal protection circuit breaker (article number 45305)</li>
<li>230 V, 16 A, max. 3,500 W</li>
<li>IP44: protected against foreign bodies and splash water</li>
</ul>
<p>The post <a href="https://as-schwabe.de/eng/product/prcd-s-extension-cables/">PRCD-S extension cables</a> first appeared on <a href="https://as-schwabe.de/eng">as - Schwabe</a>.</p>]]></description>
										<content:encoded><![CDATA[<p><strong>What is a PRCD-S?</strong><br /> Portable residual current devices with protective conductor detection or protective conductor monitoring are known as PRCD-S (Portable Residual Current Device-Safety). They are used to protect people from electrical accidents and are connected like an extension cable between an electrical load, e.g. a power tool, and a socket outlet.</p>
<p>Further information can be found <a href="t3://file?uid=1315" target="_blank">here</a>.</p>
<h3>Versions</h3>
<table>
<thead>
<tr>
<th class="text-left" scope="col">PRCD-S extension cables</th>
<th scope="col">PU</th>
<th class="text-right" scope="col">Item no.</th>
</tr>
</thead>
<tbody>
<tr>
<td>Earthing contact coupling with protective cap</td>
<td class="text-center">1</td>
<td class="text-right">45458</td>
</tr>
<tr>
<td>3-way solid rubber protective contact coupling with protective flap</td>
<td class="text-center">1</td>
<td class="text-right">45460</td>
</tr>
</tbody>
</table>
<h3>Details</h3>
<div class="table-container">
<table>
<thead>
<tr>
<th>Security</th>
</tr>
</thead>
<tbody>
<tr>
<td>
<div>
<p>Tested according to:<br /> DIN VDE 0661:1988-04<br /> DIN EN 50525-2  <br /> DIN VDE 0620</p>
</div>
<div class="image-cell"><img decoding="async" src="https://as-schwabe.de/wp-content/uploads/2024/12/IP44_.svg" alt="[1081]" /><img decoding="async" src="https://as-schwabe.de/wp-content/uploads/2024/12/CE_schwarz.svg" alt="[1085]" /><img decoding="async" src="https://as-schwabe.de/wp-content/uploads/2024/12/BGI_2019.svg" alt="[1243]" /><img decoding="async" src="https://as-schwabe.de/wp-content/uploads/2024/12/Icon_K2_2019.svg" alt="[1246]" /><img decoding="async" src="https://as-schwabe.de/wp-content/uploads/2025/01/Icon_PRCDS_nicht_mit_Handschuhen_verwenden_01.svg" alt="[1486]" /></div>
</td>
</tr>
</tbody>
</table>
<table>
<thead>
<tr>
<th>Technical data</th>
</tr>
</thead>
<tbody>
<tr>
<td>
<p>230 V, 16 A, max. 3,500 W</p>
<div class="image-cell"><img decoding="async" src="https://as-schwabe.de/wp-content/uploads/2024/12/Icon_Made_in_Germany.svg" alt="[DE]" /></div>
</td>
</tr>
</tbody>
</table>
<table>
<thead>
<tr>
<th>Use</th>
</tr>
</thead>
<tbody>
<tr>
<td>
<div class="image-cell"><img decoding="async" src="https://as-schwabe.de/wp-content/uploads/2024/12/as-schwabe-technik-produkte-einsatzgebiet-gewerbe-icon-1.svg" alt="[1]" /><img decoding="async" src="https://as-schwabe.de/wp-content/uploads/2024/12/as-schwabe-technik-produkte-einsatzgebiet-aussen-icon.svg" alt="[2]" /><img decoding="async" src="https://as-schwabe.de/wp-content/uploads/2024/12/as-schwabe-technik-produkte-einsatzgebiet-innen-icon.svg" alt="[3]" /></div>
</td>
</tr>
</tbody>
</table></div>
<p><strong>How does a PRCD-S work?</strong><br /> When attempting to switch on the PRCD-S, the wiring of the supply line is checked. The PRCD-S can only be switched on if the wiring is faultless. Only then can the connected appliance be switched on. With this function, the PRCD-S prevents accidents caused by faulty electrical installations, such as a missing protective earth conductor. Such faults can usually only be recognised by closer inspection and are therefore particularly dangerous. A PRCD-S only offers this protection if it is switched on without gloves, i.e. with direct skin contact, as a measurement of the earth potential through the user's body is carried out during the switch-on process. During operation of the electrical load, the PRCD-S assumes the function of a residual current circuit breaker and thus protects the user against dangerous currents that can be caused by defective electrical equipment. In addition, the PRCD-S has an undervoltage release. This prevents devices, such as cut-off grinders, from switching on again automatically after a power failure as soon as power is available again.</p>
<p> <strong>Why do we strongly recommend using it?</strong><br /> The Institute for Research into Electrical Accidents (BG ETEM) counted more than 3800 electrical accidents in 2018. Many of these can be avoided by using a PRCD-S. In order to increase safety, especially on construction sites, the BG BAU has therefore drawn up an accident prevention regulation which states that: "A company must ensure that electrical installations and equipment may only be operated in accordance with electrotechnical regulations and that any defects found must be rectified immediately. If there is an urgent danger, the defective equipment must not be used." To comply with this regulation, use cables with built-in PRCD-S on the construction site. Companies and employees are therefore on the safe side, investing directly in health and saving money in the long term.</p><p>The post <a href="https://as-schwabe.de/eng/product/prcd-s-extension-cables/">PRCD-S extension cables</a> first appeared on <a href="https://as-schwabe.de/eng">as - Schwabe</a>.</p>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>PRCD-S safety cable reel</title>
		<link>https://as-schwabe.de/eng/product/prcd-s-safety-cable-reel/</link>
		
		<dc:creator><![CDATA[wp-as-admin]]></dc:creator>
		<pubdate>Tue, 07 Jan 2025 03:45:44 +0000</pubdate>
				<guid ispermalink="false">https://as2025.as-schwabe.de/?post_type=product&#038;p=9010</guid>

					<description><![CDATA[<p><strong>Xpert's PRCD-S safety cable reel</strong></p>
<ul>
<li>Drum body made of robust, highly break-resistant special plastic</li>
<li>with sturdy, shock-absorbing X-double tube frame with star grip brake</li>
<li>Frame with ergonomic, non-slip 2-component handle and cable guide</li>
<li>with site cable made of polyurethane H07BQ-F <strong>3G2,5</strong></li>
<li>with built-in thermal circuit breaker</li>
<li>with PRCD-S personal protection circuit breaker (art. no. 45305)</li>
<li>with 3 earthed socket outlets with safety hinged lids and hammer marks</li>
<li class="translation-block">Fault currents are detected in fractions of a second and the power supply is interrupted. The <strong>PRCD-S</strong> therefore offers reliable protection against electric shocks and is approved by the employers' liability insurance association.</li>
<li class="translation-block"><strong>CAUTION:</strong> The switch-on button of the<strong> PRCD-S</strong> must be pressed with the bare hand to activate the protective function. Do not use with gloves!</li>
<li>IP44: protected against foreign bodies and splash water</li>
</ul>
<p>The post <a href="https://as-schwabe.de/eng/product/prcd-s-safety-cable-reel/">PRCD-S safety cable reel</a> first appeared on <a href="https://as-schwabe.de/eng">as - Schwabe</a>.</p>]]></description>
										<content:encoded><![CDATA[<div data-elementor-type="product-post" data-elementor-id="9010" class="elementor elementor-9010" data-elementor-post-type="product">
						<div class="elementor-element elementor-element-5ee33a46 e-flex e-con-boxed e-con e-parent" data-id="5ee33a46" data-element_type="container">
					<div class="e-con-inner">
					<div class="elementor-element elementor-element-257261ea elementor-widget elementor-widget-text-editor" data-id="257261ea" data-element_type="widget" data-widget_type="text-editor.default">
									<p>As<strong> PRCD-S</strong> (Portable Residual Current Device-Safety) are portable residual current devices with protective conductor detection or protective conductor monitoring. They are used to protect people from<br />electrical accidents and are connected like an extension cable between an electrical consumer, e.g. a power tool, and a socket.</p><h3>Versions</h3><table><thead><tr><th class="text-left" scope="col">Xpert's PRCD-S safety cable reel</th><th scope="col">ø mm</th><th scope="col">PU/pallet</th><th class="text-right" scope="col">Item no.</th></tr></thead><tbody><tr><td>40 m site cable made of polyurethane H07BQ-F 3G<strong>2,5</strong></td><td class="text-center">320</td><td class="text-center">1/48</td><td class="text-right">23829</td></tr></tbody></table><h3>Details</h3><div class="table-container"><table><thead><tr><th>Security</th></tr></thead><tbody><tr><td><div><p>Tested according to:<br />DIN VDE 0661:1988-04<br />EN 61242<br />DIN VDE 0620-2-1 <br />DIN EN 50525-2</p></div><div class="image-cell"><img decoding="async" src="https://as-schwabe.de/wp-content/uploads/2024/12/IP44_.svg" alt="[1081]" /><img decoding="async" src="https://as-schwabe.de/wp-content/uploads/2024/12/CE_schwarz.svg" alt="[1085]" /><img decoding="async" src="https://as-schwabe.de/wp-content/uploads/2024/12/BGI_2019.svg" alt="[1243]" /><img decoding="async" src="https://as-schwabe.de/wp-content/uploads/2024/12/Icon_K2_2019.svg" alt="[1246]" /><img decoding="async" src="https://as-schwabe.de/wp-content/uploads/2024/12/Icon_Hammerzeichen_schwarz.svg" alt="[1369]" /></div></td></tr></tbody></table><table><thead><tr><th>Technical data</th></tr></thead><tbody><tr><td><p>Rated residual current: 30 mA<br />Trigger time: &amp;lt 30 ms<br />230 V, 16 A, max. 3500 W</p><div class="image-cell"><img decoding="async" src="https://as-schwabe.de/wp-content/uploads/2024/12/Icon_Made_in_Germany.svg" alt="[DE]" /></div></td></tr></tbody></table><table><thead><tr><th>Use</th></tr></thead><tbody><tr><td><div class="image-cell"><img decoding="async" src="https://as-schwabe.de/wp-content/uploads/2024/12/as-schwabe-technik-produkte-einsatzgebiet-gewerbe-icon-1.svg" alt="[1]" /><img decoding="async" src="https://as-schwabe.de/wp-content/uploads/2024/12/as-schwabe-technik-produkte-einsatzgebiet-aussen-icon.svg" alt="[2]" /><img decoding="async" src="https://as-schwabe.de/wp-content/uploads/2024/12/as-schwabe-technik-produkte-einsatzgebiet-innen-icon.svg" alt="[3]" /></div></td></tr></tbody></table></div><p><strong>How does a PRCD-S work?</strong><br />When attempting to switch on the PRCD-S, the wiring of the supply line is checked. The PRCD-S can only be switched on if the wiring is faultless. Only then can the connected appliance be switched on. With this function, the PRCD-S prevents accidents caused by faulty electrical installations, such as a missing protective earth conductor. Such faults can usually only be recognised by closer inspection and are therefore particularly dangerous. A PRCD-S only offers this protection if it is switched on without gloves, i.e. with direct skin contact, as a measurement of the earth potential through the user's body is carried out during the switch-on process. During operation of the electrical load, the PRCD-S assumes the function of a residual current circuit breaker and thus protects the user against dangerous currents that can be caused by defective electrical equipment. In addition, the PRCD-S has an undervoltage release. This prevents devices, such as cut-off grinders, from switching on again automatically after a power failure as soon as power is available again.</p><p><strong>Why do we strongly recommend using it?</strong><br />Many electrical accidents can be avoided by using a PRCD-S. In order to increase safety, especially on construction sites, the BG BAU has therefore drawn up an accident prevention regulation which states that:<br /><em>"A company must ensure that the electrical systems and equipment may only be operated in accordance with the electrotechnical regulations and that any defects identified must be rectified immediately. If there is an urgent danger, the defective equipment must not be used."</em><br />To comply with this regulation, use cables with built-in PRCD-S on the construction site! Companies and employees are therefore on the safe side, investing directly in health and saving money in the long term.</p>								</div>
					</div>
				</div>
				</div><p>The post <a href="https://as-schwabe.de/eng/product/prcd-s-safety-cable-reel/">PRCD-S safety cable reel</a> first appeared on <a href="https://as-schwabe.de/eng">as - Schwabe</a>.</p>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Cable reel with PRCD personal protection plug</title>
		<link>https://as-schwabe.de/eng/product/cable-reel-with-prcd-personal-protection-plug/</link>
		
		<dc:creator><![CDATA[Jessica Zaremba]]></dc:creator>
		<pubdate>Tue, 07 Jan 2025 03:45:12 +0000</pubdate>
				<guid ispermalink="false">https://as2025.as-schwabe.de/?post_type=product&#038;p=8883</guid>

					<description><![CDATA[<ul>
<li>Drum body made of robust, highly break-resistant special plastic</li>
<li>with stable, shock-absorbing and galvanised single base frame with parking brake</li>
<li>Frame with ergonomically shaped handle and patented cable guide</li>
<li>with built-in thermal circuit breaker</li>
<li>with function display and test circuit, with electronic measuring device</li>
<li>with heavy rubber cable H07RN-F 3G1.5</li>
<li>with PRCD safety plug</li>
<li>with 3 earthed socket outlets with safety hinged lids and hammer marks</li>
<li>Rated residual current 30 mA</li>
<li>Undervoltage release</li>
<li>Triggering time less than 30 ms</li>
<li>IP44: protected against foreign bodies and splash water</li>
</ul>
<p>The post <a href="https://as-schwabe.de/eng/product/cable-reel-with-prcd-personal-protection-plug/">Cable reel with PRCD personal protection plug</a> first appeared on <a href="https://as-schwabe.de/eng">as - Schwabe</a>.</p>]]></description>
										<content:encoded><![CDATA[<h3>Versions</h3>
<table>
<thead>
<tr>
<th class="text-left" scope="col">Cable reel with PRCD</th>
<th scope="col">ø mm</th>
<th scope="col">PU/pallet</th>
<th class="text-right" scope="col">Item no.</th>
</tr>
</thead>
<tbody>
<tr>
<td>40 m heavy-duty rubber hose cable H07RN-F 3G1.5</td>
<td class="text-center">285</td>
<td class="text-center">1/64</td>
<td class="text-right">10829</td>
</tr>
</tbody>
</table>
<h3>Details</h3>
<div class="table-container">
<table>
<thead>
<tr>
<th>Security</th>
</tr>
</thead>
<tbody>
<tr>
<td>
<div>
<p>Tested according to:<br /> EN 61242<br /> DIN VDE 0620<br /> VDE 0661<br /> DIN EN 50525-2</p>
</div>
<div class="image-cell"><img decoding="async" src="https://as-schwabe.de/wp-content/uploads/2024/12/IP44_.svg" alt="[1081]" /><img decoding="async" src="https://as-schwabe.de/wp-content/uploads/2024/12/CE_schwarz.svg" alt="[1085]" /></div>
</td>
</tr>
</tbody>
</table>
<table>
<thead>
<tr>
<th>Technical data</th>
</tr>
</thead>
<tbody>
<tr>
<td>
<p>230 V, 16 A, max. 3500W<br /> Rated residual current 30mA</p>
<div class="image-cell"><img decoding="async" src="https://as-schwabe.de/wp-content/uploads/2024/12/Icon_Made_in_Germany.svg" alt="[DE]" /></div>
</td>
</tr>
</tbody>
</table>
<table>
<thead>
<tr>
<th>Use</th>
</tr>
</thead>
<tbody>
<tr>
<td>
<div class="image-cell"><img decoding="async" src="https://as-schwabe.de/wp-content/uploads/2024/12/as-schwabe-technik-produkte-einsatzgebiet-gewerbe-icon-1.svg" alt="[1]" /><img decoding="async" src="https://as-schwabe.de/wp-content/uploads/2024/12/as-schwabe-technik-produkte-einsatzgebiet-aussen-icon.svg" alt="[2]" /></div>
</td>
</tr>
</tbody>
</table></div><p>The post <a href="https://as-schwabe.de/eng/product/cable-reel-with-prcd-personal-protection-plug/">Cable reel with PRCD personal protection plug</a> first appeared on <a href="https://as-schwabe.de/eng">as - Schwabe</a>.</p>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>PRCD extension cable</title>
		<link>https://as-schwabe.de/eng/product/prcd-extension-cable/</link>
		
		<dc:creator><![CDATA[wp-as-admin]]></dc:creator>
		<pubdate>Tue, 07 Jan 2025 03:45:11 +0000</pubdate>
				<guid ispermalink="false">https://as2025.as-schwabe.de/?post_type=product&#038;p=8882</guid>

					<description><![CDATA[<ul>
<li>Heavy rubber hose line</li>
<li>with earthing contact plug and coupling with protective cap</li>
<li>with function display and test circuit, with electronic measuring device</li>
<li>Rated residual current 30 mA</li>
<li>Auslösezeit &#60;30 ms</li>
<li>230 V, 16 A, max. 3,500 W</li>
<li>IP44: protected against foreign bodies and splash water</li>
</ul>
<p>The post <a href="https://as-schwabe.de/eng/product/prcd-extension-cable/">PRCD extension cable</a> first appeared on <a href="https://as-schwabe.de/eng">as - Schwabe</a>.</p>]]></description>
										<content:encoded><![CDATA[<h3>Versions</h3>
<table>
<thead>
<tr>
<th class="text-left" scope="col">PRCD extension cable</th>
<th scope="col">PU</th>
<th class="text-right" scope="col">Item no.</th>
</tr>
</thead>
<tbody>
<tr>
<td>2 x 1.5 m H07RN-F 3G1.5</td>
<td class="text-center">1</td>
<td class="text-right">45222</td>
</tr>
</tbody>
</table>
<h3>Details</h3>
<div class="table-container">
<table>
<thead>
<tr>
<th>Security</th>
</tr>
</thead>
<tbody>
<tr>
<td>
<div>
<p>Tested according to<br /> DIN VDE 0620<br /> VDE 0661<br /> DIN EN 50525-2</p>
</div>
<div class="image-cell"><img decoding="async" src="https://as-schwabe.de/wp-content/uploads/2024/12/IP44_.svg" alt="[1081]" /><img decoding="async" src="https://as-schwabe.de/wp-content/uploads/2024/12/CE_schwarz.svg" alt="[1085]" /></div>
</td>
</tr>
</tbody>
</table>
<table>
<thead>
<tr>
<th>Technical data</th>
</tr>
</thead>
<tbody>
<tr>
<td>
<p>230 V, 16 A, max. 3.5 kW<br /> Rated residual current 30 mA<br /> Release time &amp;lt30 mS</p>
<div class="image-cell"><img decoding="async" src="https://as-schwabe.de/wp-content/uploads/2024/12/Icon_Made_in_Germany.svg" alt="[DE]" /></div>
</td>
</tr>
</tbody>
</table>
<table>
<thead>
<tr>
<th>Use</th>
</tr>
</thead>
<tbody>
<tr>
<td>
<div class="image-cell"><img decoding="async" src="https://as-schwabe.de/wp-content/uploads/2024/12/as-schwabe-technik-produkte-einsatzgebiet-gewerbe-icon-1.svg" alt="[1]" /><img decoding="async" src="https://as-schwabe.de/wp-content/uploads/2024/12/as-schwabe-technik-produkte-einsatzgebiet-aussen-icon.svg" alt="[2]" /></div>
</td>
</tr>
</tbody>
</table></div>
<p><strong>What is the difference between a PRCD and a PRCD-S?</strong></p>
<p> The PRCD is a portable personal protection switch with an electronic residual current release and undervoltage release.</p>
<ul>
<li>It recognises residual currents that occur, for example, when a faulty electrical appliance is touched and interrupts the current so quickly that life-threatening accidents can be prevented.</li>
<li>It also has an undervoltage release that switches off in the event of a mains voltage failure to prevent secondary accidents.</li>
</ul>
<p> The PRCD-S is an all-pole switching, portable residual current device with electronic residual current evaluation, designed as an intermediate cord device.</p>
<p> <strong>Additional functions compared to the PRCD:</strong></p>
<ul>
<li>Check the socket outlet to ensure that phase L, neutral conductor N and protective conductor PE are present, correctly connected and not reversed.</li>
<li>Only allows power to be drawn from a safe socket.</li>
<li>Checks the protective conductor when switching on.</li>
<li>Monitors the protective conductor during operation.</li>
<li>Cannot be switched on if a fault is detected.</li>
<li>Switches off automatically as soon as a fault occurs (e.g. protective conductor breakage).</li>
<li>Does not switch off if external voltage is applied to the protective conductor, e.g. by drilling into a</li>
<li>External line. As the PRCD-S does not switch off in this case, the upstream protective device can respond and interrupt the circuit.</li>
</ul>
<p><strong>The employers' liability insurance associations recommend</strong> As a supply point on small construction sites Protective distribution boards and portable protective devices with protective conductor monitoring (PRCD-S)!</p><p>The post <a href="https://as-schwabe.de/eng/product/prcd-extension-cable/">PRCD extension cable</a> first appeared on <a href="https://as-schwabe.de/eng">as - Schwabe</a>.</p>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>PRCD personal protection plug</title>
		<link>https://as-schwabe.de/eng/product/prcd-personal-protection-plug/</link>
		
		<dc:creator><![CDATA[wp-as-admin]]></dc:creator>
		<pubdate>Tue, 07 Jan 2025 03:45:11 +0000</pubdate>
				<guid ispermalink="false">https://as2025.as-schwabe.de/?post_type=product&#038;p=8879</guid>

					<description><![CDATA[<ul>
<li>30 mA personal protection plug</li>
<li>Undervoltage release</li>
<li>Triggering time less than 30 ms</li>
<li>Reliable protection against dangerous electric shocks</li>
<li>Fault currents are detected in fractions of a second and the power supply is interrupted</li>
<li>with function display and test circuit, with electronic measuring device</li>
<li>for cables up to max. 3G2.5mm²</li>
<li>230 V, 16 A, max. 3,500 W</li>
<li>IP44: protected against foreign bodies and splash water</li>
</ul>
<p>The post <a href="https://as-schwabe.de/eng/product/prcd-personal-protection-plug/">PRCD personal protection plug</a> first appeared on <a href="https://as-schwabe.de/eng">as - Schwabe</a>.</p>]]></description>
										<content:encoded><![CDATA[<h3>Versions</h3>
<table>
<thead>
<tr>
<th class="text-left" scope="col">PRCD personal protection plug</th>
<th scope="col">PU</th>
<th class="text-right" scope="col">Item no.</th>
</tr>
</thead>
<tbody>
<tr>
<td>for fixed connection to the supply line up to max. 3G2.5mm²</td>
<td class="text-center">1</td>
<td class="text-right">45209</td>
</tr>
</tbody>
</table>
<h3>Details</h3>
<div class="table-container">
<table>
<thead>
<tr>
<th>Security</th>
</tr>
</thead>
<tbody>
<tr>
<td>
<div>
<p>Tested according to <br /> DIN VDE 0620<br /> VDE 0661</p>
</div>
<div class="image-cell"><img decoding="async" src="https://as-schwabe.de/wp-content/uploads/2024/12/CE_schwarz.svg" alt="[1085]" /></div>
</td>
</tr>
</tbody>
</table>
<table>
<thead>
<tr>
<th>Technical data</th>
</tr>
</thead>
<tbody>
<tr>
<td>
<p>230 V, 16 A, max. 3,500 W</p>
<div class="image-cell"><img decoding="async" src="https://as-schwabe.de/wp-content/uploads/2024/12/Icon_Made_in_Germany.svg" alt="[DE]" /></div>
</td>
</tr>
</tbody>
</table>
<table>
<thead>
<tr>
<th>Use</th>
</tr>
</thead>
<tbody>
<tr>
<td>
<div class="image-cell"><img decoding="async" src="https://as-schwabe.de/wp-content/uploads/2024/12/as-schwabe-technik-produkte-einsatzgebiet-gewerbe-icon-1.svg" alt="[1]" /><img decoding="async" src="https://as-schwabe.de/wp-content/uploads/2024/12/as-schwabe-technik-produkte-einsatzgebiet-aussen-icon.svg" alt="[2]" /></div>
</td>
</tr>
</tbody>
</table></div>
<p><strong>What is the difference between a PRCD and a PRCD-S?</strong><br /> The PRCD is a portable personal protection switch with an electronic residual current release and undervoltage release.</p>
<ul>
<li>It recognises residual currents that occur, for example, when a faulty electrical appliance is touched and interrupts the current so quickly that life-threatening accidents can be prevented.</li>
<li>It also has an undervoltage release that switches off in the event of a mains voltage failure to prevent secondary accidents.</li>
</ul>
<p> The PRCD-S is an all-pole switching, portable residual current device with electronic residual current evaluation, designed as an intermediate cord device.<br /> Additional functions compared to the PRCD:</p>
<ul>
<li>Check the socket outlet to ensure that phase L, neutral conductor N and protective conductor PE are present, correctly connected and not reversed.</li>
<li>Only allows power to be drawn from a safe socket.</li>
<li>Checks the protective conductor when switching on.</li>
<li>Monitors the protective conductor during operation.</li>
<li>Cannot be switched on if a fault is detected.</li>
<li>Switches off automatically as soon as a fault occurs (e.g. protective conductor breakage).</li>
<li>Does not switch off if external voltage is applied to the protective conductor, e.g. by drilling into an external cable. As the PRCD-S does not switch off in this case, the upstream protective device may respond and interrupt the circuit.</li>
</ul>
<p>The employers' liability insurance associations recommend protective distribution boards and portable protective devices with protective conductor monitoring (PRCD-S) as a supply point on small construction sites!</p><p>The post <a href="https://as-schwabe.de/eng/product/prcd-personal-protection-plug/">PRCD personal protection plug</a> first appeared on <a href="https://as-schwabe.de/eng">as - Schwabe</a>.</p>]]></content:encoded>
					
		
		
			</item>